Combined test units G7-1U / G7-1H

BestPerformance

BestPerformance unit series

Cost-effective and user-friendly. The black and white styled touch panel simplifies operation of the test units, which are equipped with an Ethernet port as standard (optionally available: RS-232 or USB).

Combined AC test unit (HV AC)

The test unit – also available as an automated unit – permits versatile use for application scenarios in manual or automated systems for protective conductor continuity testing, insulation resistance testing and hi-pot testing of systems, parts and components. The system is rounded off by accessory components specifically configurable for this model.

With Touch-Panel: G7-1U
Without Touch-Panel: G7-1H

  • 19” slide-in system
  • High-quality metal housing
  • Access lock via configurable password entry stage
  • Service-friendly – can be replaced in just a few steps
  • Interfaces: Ethernet; RS-232-C or USB as alternatives

Hi-pot testing

0 … 2.50 • 3.00 kVAC; 0 … 10.00 • 200.0 mA; 500 VA

Voltage ramp

User-programmable for start and end of test

Protective conductor

0 … 1.2 Ω; 6 or 12 VAC; 10 … 32 A

Insulation resistance

50 … 1.20 kVDC; 10/100 MΩ • 1.00 GΩ

Nominal capacity

500 VA

Interface

Ethernet • Digital interface

Line voltage

230 V, +/−10%; 49 … 61 Hz

Form factor

19”/4 RU; depth 360 mm

Additional digital outputs

Six digital outputs for controlling an external switchover matrix

RS-232-C

Alternative interface instead of Ethernet port

USB

Alternative interface instead of Ethernet port

Software package

Elution® Device

  • 19” housing/4 RU 93-1B
  • Mobile Primus Basic test unit
  • Test gun 94-2A Z02m, 1 pc
  • Warning lamp F9-1A
  • Two-hand control F9-1L-01
  • Manual start button F9-1W
  • Test cage 94-3A/B
  • Dummy module F9-4K
  • Connection box F9-7A
  • Connection cable F9-7D/E
  • Protective conductor test probe 94-4S
Overview

We respect your privacy

We use cookies to offer you an ideal experience on our website. This includes cookies that are necessary to operate our web pages as well as cookies only used for anonymous statistical purposes, for user experience settings and for displaying customised content. You can decide which categories you want to allow. Please note that based on your settings, not all the functionalities of our site may be available.

Cookie settings

 

Without these cookies, the website cannot function correctly.

 

These cookies are used to analyse user behaviour on our website. They may count how often a user has visited the site or how long they spend on a certain web page.

 

These cookies are used to improve our website’s user experience. They may store whether you have already accessed a Google Maps map so that you won’t be shown our privacy statement again.